Multi-Maat Rioolafsluiters
Ballonplug voor een diameterbereik. Vergelijk MS-afsluiting, MSBP-bypass en HMSP-rijen; opblaasdruk en tegendruk zijn gescheiden.
- Gepubliceerd maatbereik
- DN50–1500(2–60″)
- Gepubliceerde modellen
- 40 modellen
- Max. vuldruk
- 4 bar
- Vraag naar voorraad en levertijd
- Maten op maat
- Modellen met bypass leverbaar
- Manometer en slang van 10 m inbegrepen
- EU TEST-attest
Details
Multi-size inflatable pipe plugs are temporary isolation plugs, with a separate MSBP bypass family. Published models run from MS 50-100 through MS 800-1500, each with its own maximum inflation pressure and back pressure. Confirm the measured bore and required back pressure before ordering; repair packers and resin patch installation are separate product families.
Natuurlijk rubber en hoogpolymeer nylon. Een ballonplug op deze pagina is een opblaasbare multi-maat rioolafsluiter. Lees opblaasdruk en tegendruk op de gekozen MS-, MSBP- of HMSP-rij. Elke gepubliceerde HMSP-rij noemt 4 bar maximale opblaasdruk en 2,5 bar maximale tegendruk.
Bevestig voor elk project afmetingen, materialen, bedrijfsgrenzen, inspectiedocumenten, beschikbaarheid en levervoorwaarden met Reliance.
Technische Specificaties
Alleen voorlopige kandidaten. De maat bevestigt geen geschiktheid; materiaal, defect, druk en toegang vereisen technische beoordeling.
Standaard
| Model | Max. vuldruk(bar) | Max. tegendruk(bar) | Productdiameter(mm) | Totale lengte(mm) | Nettogewicht(kg) |
|---|---|---|---|---|---|
| 3 | 2 | 47 | 330 | 0.5 | |
| 3 | 2 | 67 | 375 | 0.9 | |
| 2 | 1 | 95 | 460 | 1.5 | |
| 2 | 1 | 135 | 550 | 2.5 | |
| 2 | 1 | 182 | 610 | 4.5 | |
| 2 | 1 | 185 | 750 | 5 | |
| 1.5 | 0.5 | 283 | 770 | 13 | |
| 1.5 | 0.5 | 365 | 900 | 20 | |
| 1.5 | 0.5 | 460 | 1050 | 29 | |
| 1.2 | 0.2 | 550 | 1460 | 45 | |
| 1.2 | 0.2 | 620 | 2000 | 59 |
Elke afsluitballon wordt geleverd met een manometer en een luchtslang van 10 m.
Bypass
| Model | Max. vuldruk(bar) | Max. tegendruk(bar) | Productdiameter(mm) | Totale lengte(mm) | Nettogewicht(kg) |
|---|---|---|---|---|---|
| 2 | 1 | 182 | 610 | 9 | |
| 2 | 1 | 283 | 770 | 18 | |
| 2 | 1 | 365 | 900 | 28 | |
| 1.5 | 0.5 | 460 | 1050 | 34 | |
| 1.5 | 0.5 | 550 | 1460 | 58 | |
| 1.2 | 0.3 | 550 | 1750 | 58 | |
| 1.2 | 0.3 | 620 | 2060 | 58 |
Elke afsluitballon wordt geleverd met een manometer en een luchtslang van 10 m.
Hoge druk
- Gelijk voor alle modellen
- Max. vuldruk
- 4 bar
- Max. tegendruk
- 2.5 bar
| Model | Productdiameter(mm) | Totale lengte(mm) |
|---|---|---|
| 95 | 560 | |
| 135 | 500 | |
| 190 | 560 | |
| 290 | 610 | |
| 390 | 610 | |
| 450 | 610 | |
| 490 | 610 | |
| 550 | 610 | |
| 650 | 610 | |
| 750 | 610 | |
| 850 | 610 |
Elke afsluitballon wordt geleverd met een manometer en een luchtslang van 10 m.
Stoomballonnen
| Buisbereik(mm) | Max. vuldruk(bar) | Begindiameter(mm) | Totale lengte(mm) | Lengte A(mm) | Lengte B(mm) | Nettogewicht(kg) |
|---|---|---|---|---|---|---|
| 2 | 95 | 470 | 360 | 110 | 2 | |
| 2 | 95 | 470 | 360 | 110 | 3 | |
| 1.5 | 95 | 560 | 440 | 120 | 3.8 | |
| 1.5 | 160 | 560 | 460 | 100 | 6.5 | |
| 1.5 | 220 | 560 | 460 | 100 | 10 | |
| 1.5 | 270 | 560 | 480 | 80 | 14 | |
| 1.5 | 340 | 610 | 530 | 80 | 18 | |
| 1.5 | 400 | 610 | 530 | 80 | 25 | |
| 1.5 | 400 | 800 | 800 | 70 | 45 | |
| 1.5 | 450 | 800 | 850 | 70 | 56 | |
| 1.5 | 640 | 900 | 950 | 80 | 85 |
Geschikt voor stoom tot 150 °C.
Beschermhoezen
| Model |
|---|
| MS 100-200 |
| MS 150-300 |
| MS 200-400 |
| MS 200-500 |
| MS 300-600 |
| MS 400-800 |
| MS 500-1000 |
| MS 600-1200 |
| MS 800-1500 |
Rubberen beschermhoezen passen over de multi-size afsluitballon van hetzelfde maatbereik.
Specificaties uit de actuele prijslijst en productbrochures van Reliance. Stem de configuratie vóór bestelling af met ons team.
Zo werkt het in de buis
Vereenvoudigde illustratie, niet op schaal. Kies op basis van de gemeten binnendiameter en de modeltabel.
Productgids
Technische gids uit de Engelse brochure
Bypass pipe plug or isolation plug?
A bypass pipe plug provides a passage through the plug for a planned flow or test connection. Select the MSBP bypass configuration when that passage is required; an MS isolation plug has a different duty. Confirm the bypass connection and project flow requirements against the selected model rather than assuming the pipe diameter establishes bypass capacity.
The brochure separates multi-size pipe plugs without bypass from MSBP bypass plugs. It lists each model’s maximum inflation pressure, maximum back pressure, product diameter, overall length and net weight.
The catalogue describes rubber and high-polymer nylon construction with integrated vulcanization. Model selection depends on the pipe dimensions and the required isolation or bypass arrangement.
Accessories and protective sleeves
The brochure lists a pressure gauge and a 10-metre air hose with each plug. Protective rubber sleeves are listed separately for MS 100–200 through MS 800–1500. The factory test report that arrives with the plug has to trace the tested specimen to the order line; the [pipe plug factory test report checklist](/blog/pipe-plug-factory-test-report) lists the fields to check before you accept the delivery.
Inflation pressure is the pressure inside the plug; the brochure lists a separate back-pressure limit. Use the values for the exact configuration rather than treating the two pressure columns as interchangeable.
HMSP rows and steam-plug rows
The catalogue also publishes a high-pressure table, HMSP 100-200 through HMSP 1200-1400. Every HMSP row lists 4 bar maximum inflation pressure and 2.5 bar maximum back pressure. That table does not publish a weight. These rows are separate from the MS isolation rows, whose pressure pairs are lower on the larger sizes.
Steam-plug rows are on this page as well. The published note rates them for steam up to 150 °C. They are not the TP testing-plug series. The accessory note for a pressure gauge and a 10 m air hose is on the MS, MSBP and HMSP tables. The steam-plug table publishes the temperature note instead.
Where flow has to be controlled before a localized sleeve repair, the trenchless installation guide points to an inflatable pipe plug matched to the pipe size and back pressure. Use the row for the selected model, then state whether the order is urgent air freight or sea freight.
Middle East / GCC enquiries
The Dubai office coordinates regional enquiries: TH65 Alandulus, Jumeirah Golf Estate, Dubai, United Arab Emirates. Pipe plugs are shipped from China. Reliance is headquartered in Wenzhou, with manufacturers in Qingdao.
Qatar, Saudi Arabia and the United Arab Emirates are listed customer countries. Send enquiries for those destinations, and for other countries, to sales@reliancetrenchless.com or WhatsApp +86 188 6774 8857. Reliance exhibited at Trenchless Middle East 2024, Dubai, UAE.
Export orders are wrapped, labelled and crated on pallets. Air freight is fast air cargo for urgent or time-sensitive orders; sea, land and rail are also published routes. Availability and delivery are confirmed per project.
Measured inner diameter, and the nominal DN if that is the only size on the drawing.
The medium in the pipe.
Working conditions, including the inflation pressure and back pressure the plug must hold.
Quantity.
Destination: Qatar, the United Arab Emirates, Saudi Arabia, or another country.
Whether air freight is needed for an urgent order, or sea freight is acceptable. Air freight is optional.
Frequently asked questions about multi-size pipe plugs
Is a pipe balloon plug the same as a pneumatic pipe plug?
On this page, yes. A pipe balloon plug, an inflatable pipe stopper and a pneumatic pipe plug are names buyers use for these multi-size inflatable pipe plugs.
The catalogue still separates temporary isolation plugs, MS 50-100 through MS 800-1500, from the MSBP bypass family, MSBP 200-300 through MSBP 800-1500. They are not repair packers.
Bron: PDF · 2
Casestudy’s
Projectfoto’s en video’s van Reliance-orders en -installaties.
DN5500-hogedrukleidingafsluiters, Abu Dhabi
Korte video’s
1Verpakking en levering
Hoe orders worden verpakt en geladen voor verzending.
Originele documenten
Lees de gids en specificaties online. De originele bestanden blijven hieronder beschikbaar.
EU TEST heeft de technische dossiers van zes van onze productgroepen getoetst aan de vermelde EU-wetgeving en normen. Dit zijn vrijwillige verklaringen, geen certificaten van een aangemelde instantie.
Aankoopgidsen
Toepassingsoverzicht
Vergelijk afsluiters voor meerdere maten, één maat en testen voor leidingisolatie, stroomomleiding en leidingtesten.
Leidingafsluiters en testenToepassingenTechnische aanvraag
Vermeld deze gegevens in uw productaanvraag zodat Reliance de aanvraag kan beoordelen.
Leidingdiameter, materiaal en defect of geplande taak
Product of model, afmetingen en hoeveelheid
Druk, bedrijfsomstandigheden, toegang en installatiebeperkingen
Norm, inspectiedocumenten, bestemming en gewenste datum
Bevestig voor elk project afmetingen, materialen, bedrijfsgrenzen, inspectiedocumenten, beschikbaarheid en levervoorwaarden met Reliance.
Offerte aanvragen: Multi-Maat Rioolafsluiters