Inflatable Pipe Plugs and Testing

Compare a pipe balloon plug or pneumatic pipe plug for isolation, bypass and testing. Pipe inflation pressure and back pressure are separate model limits.

Buyer’s guides

How to choose an inflatable pipe plug

Start with the job: isolate a pipe section, provide a bypass for flow, or prepare for a pipeline test. Then compare the measured internal diameter, available access and pressure conditions with the selected model. A product family name alone does not establish suitability.

What is a pipe balloon plug?

A pipe balloon plug is another name for an inflatable pipe plug on this page. Buyers also say inflatable pipe stopper or pneumatic pipe plug. An inflatable sewer plug is the same inflatable plug when the pipe is a sewer; choose the testing, isolation or bypass row for the task.

Compare plug types, then open each product’s published specifications and brochure before selection.
Product and specificationsIntended taskWhat to confirm
Multi-Size Inflatable Pipe PlugsPipe isolation across a published diameter range, with or without a bypass configuration.Compare MS and MSBP models, pipe range, deflated dimensions, inflation pressure and maximum back pressure.
Single Size Pipe PlugsPipe sealing where a plug is selected for a nominal pipe size.Match the measured internal diameter to the model and review deflated length and model-specific pressure limits.
Inflatable Test Plug (TP-DN150–TP-DN1000)Hydraulic or air testing of pipes and sewers.Review the TP brochure table and confirm the actual fit dimensions, test conditions and permitted back pressure.

Bypass or non-bypass pipe plugs?

The multi-size brochure separates MS plugs without bypass from MSBP bypass plugs. Specify whether flow diversion is required, then confirm the bypass arrangement for the chosen model. Review the multi-size pipe plug guide alongside the specification table.

Frequently asked questions about pipe inflation

What is pipe inflation pressure?

Pipe inflation pressure is the pressure inside the inflatable plug. Catalogue tables label that column “Max. inflation pressure”. It is not the pressure of the pipe contents the plug is holding back.

How is back pressure different from inflation pressure?

Back pressure acts on the plug from the pipe contents and can push the plug along the pipe. The catalogue lists it separately as “Max. back pressure”. An inflation figure does not set the permitted back pressure. Use the model table on this page for the published pair, then confirm the exact row in the quotation before ordering.

Which inflation and back-pressure limits are published?

Read the row for the selected model. These published pairs are not one rating for every plug.

  • Multi-size (MS) rows use maximum inflation pressure and maximum back pressure of 3 bar / 2 bar, 2 bar / 1 bar, 1.5 bar / 0.5 bar or 1.2 bar / 0.2 bar, depending on the model. MS 50-100 and MS 70-150 are the 3 bar / 2 bar rows. MS 600-1200 and MS 800-1500 are the 1.2 bar / 0.2 bar rows.

  • MSBP bypass rows are a separate table: 2 bar / 1 bar, 1.5 bar / 0.5 bar or 1.2 bar / 0.3 bar. Do not copy a non-bypass figure onto a bypass model.

  • Every high-pressure (HMSP) row lists 4 bar maximum inflation pressure and 2.5 bar maximum back pressure, from HMSP 100-200 through HMSP 1200-1400. That table does not publish a weight.

  • Steam-plug rows are on the multi-size page, not on the testing plug page. They list 2 bar or 1.5 bar inflation pressure, do not publish a back-pressure column, and are rated for steam up to 150 °C.

  • Each single-size catalogue row lists 2 bar maximum inflation pressure and 1 bar maximum back pressure. The brochure’s DN300–6000 range and 1–30 m water-sealing heights are broader than those rows and are not a pressure rating for every model.

  • Testing plugs are published as a 4 bar series and a 6 bar series, eight models in each, from TP-DN150 to TP-DN1000. The 4 bar series lists 4 bar maximum inflation pressure and 3 bar maximum back pressure on every row. The 6 bar series lists 6 bar and 5 bar. The brochure sentence that gives a working pressure of 4 bar and a back pressure of 3 bar matches the 4 bar series. A model name is not the pipe diameter: TP-DN150 is described as 100 mm / 4 in.

Is an inflatable pipe plug a CIPP packer?

No. Inflating a pipe plug closes a bore for isolation, bypass or a pipeline test. A repair packer positions repair material for a localized point repair and is a different product. Do not select a sealing plug as a CIPP or point-repair packer.

Information for a pipe plug enquiry

Send the measured pipe diameter and material, isolation or testing task, bypass requirement, pressure conditions, access constraints and quantity. Include the model and source table you are using so Reliance can review the configuration and resolve any specification differences. Follow the confirmed operating instructions for the selected product.

Middle East / GCC enquiries

The Dubai office coordinates regional enquiries: TH65 Alandulus, Jumeirah Golf Estate, Dubai, United Arab Emirates. Pipe plugs are shipped from China. Reliance is headquartered in Wenzhou, with manufacturers in Qingdao. Qatar, Saudi Arabia and the United Arab Emirates are listed customer countries. Send enquiries for those destinations, and for other countries, to sales@reliancetrenchless.com or WhatsApp +86 188 6774 8857. Reliance exhibited at Trenchless Middle East 2024, Dubai, UAE.

Export orders are wrapped, labelled and crated on pallets. Air freight is fast air cargo for urgent or time-sensitive orders; sea, land and rail are also published routes. Availability and delivery are confirmed per project. Air freight is optional.

  • Measured inner diameter, and the nominal DN if that is the only size on the drawing.

  • The medium in the pipe.

  • Working conditions, including the inflation pressure and back pressure the plug must hold.

  • Quantity.

  • Destination: Qatar, the United Arab Emirates, Saudi Arabia, or another country.

  • Whether air freight is needed for an urgent order, or sea freight is acceptable.

Pipe plug back-pressure and water-head calculator

Convert a static water head to pressure at the plug, then compare it with the maximum back pressure published for each model. Use the upstream water level above the plug, not the pipe diameter.

Static pressure: 0.49 bar · 7.1 psi

11 published models cover DN300; 11 list a back-pressure limit at or above this static head.

Published back-pressure limits compared with the calculated static head. Surge, flow and temperature are not included.
ProductModelPipe rangeMax back pressureCheck
Test plugTP-DN300DN300–3005.0 barRated for this head
Test plugTP-DN300DN300–3003.0 barRated for this head
Multi-size plugHMSP 200-400DN200–4002.5 barRated for this head
Multi-size plugHMSP 300-600DN300–6002.5 barRated for this head
Multi-size plugMS 150-300DN150–3001.0 barRated for this head
Multi-size plugMS 200-400DN200–4001.0 barRated for this head
Multi-size plugMS 200-500DN200–5001.0 barRated for this head
Multi-size plugMSBP 200-300DN200–3001.0 barRated for this head
Multi-size plugMSBP 300-500DN300–5001.0 barRated for this head
Single-size plugSS 300DN300–3001.0 barRated for this head
Multi-size plugMS 300-600DN300–6000.5 barRated for this head

Static head only. Add the project allowance for surge, flow, pipe condition and temperature, and confirm the selected model, accessory arrangement and test procedure with Reliance. A catalogue back-pressure figure is not a project approval.

How these products work inside the pipe

Cutaway of a buried pipe: an inflatable plug is placed and inflated, holding back the flow upstream.
Inflatable pipe plugThe plug is inflated in the pipe to hold back flow for isolation, bypass or testing. Inflation pressure and back pressure are separate limits for each model.

Simplified illustration, not to scale. Select by the measured internal diameter and the model table.

Multi-Size Inflatable Pipe Plugs

Multi-Size Inflatable Pipe Plugs

Natural rubber and high polymer nylon. A pipe balloon plug on this page is a multi-size inflatable pipe plug. Read inflation pressure and back pressure on the selected MS, MSBP or HMSP row. Every published HMSP row lists 4 bar maximum inflation pressure and 2.5 bar maximum back pressure.

Single Size Pipe Plugs

Single Size Pipe Plugs

Single-size inflatable pipe plugs use imported rubber and high-tensile interwoven fibers. Each published catalogue row from SS 300 to SS 4000 lists 2 bar maximum inflation pressure and 1 bar maximum back pressure. The brochure range DN300–6000 is broader than those rows.

Inflatable Test Plug (TP-DN150–TP-DN1000)

Inflatable Test Plug (TP-DN150–TP-DN1000)

Inflatable test plug for hydraulic or air testing of pipes and sewers. Published TP rows run from TP-DN150 to TP-DN1000 in a 4 bar series and a 6 bar series. Steam plugs are a separate table on the multi-size page. Confirm the test pressure, pipe fit and accessory set before ordering.

Project Review

Confirm dimensions, materials, operating limits, inspection documents, availability and delivery terms with Reliance for each project.

  • Pipe diameter, material and defect or intended task

  • Selected product or model, dimensions and quantity

  • Pressure or service conditions, access and installation constraints

  • Required standard, inspection documents, destination and target date

Application Overview