Video · English

Internal Pipe Repair Sleeve: How Long a Crack It Covers

A 400 mm internal pipe repair sleeve seals a crack of at most about 190 mm: 290 mm of sealing width minus 50 mm of sound pipe on each side.

2 min 47 secEnglish

Application Overview

The coverage rule in this video uses the Instant-Lock Small 400 mm sleeve: about 290 mm of sealing width and at least 50 mm of sound pipe on each side up to DN300. Confirm the measured bore, ovality and defect length with Reliance before ordering.

Chapters

Each chapter opens the video at that point on YouTube. Read the script under each chapter. From the subtitle track delivered with the video. Refer to the video and product documentation for technical details.

  1. 0:00

    Internal pipe repair sleeve defect coverage

    An internal pipe repair sleeve four hundred millimetres long cannot seal a four hundred millimetre crack. So how long a crack can it cover? One rule decides. The sleeve is a stainless steel shell inside an EPDM rubber jacket. A packer expands it against the pipe wall, and a locking gear holds it open.

  2. 0:19

    Repair sleeve steel length vs sealing width

    Under a live street, a CCTV crawler finds a crack in the sewer. The fix will be a sleeve, sent in from the manhole, with no trench. But before anyone orders one, the crack is measured from start to stop. Now look at the sleeve from the side. The steel shell runs the full four hundred millimetres. The rubber jacket stops short of the steel at both ends. Only the ribs at each edge seal, and they sit about two hundred and ninety millimetres apart.

  3. 0:47

    Sound pipe landing on each side of the defect

    Those ribs have to press on sound pipe, never on the crack itself. Up to DN300, that means at least fifty millimetres of sound pipe on each side. So every millimetre of crack eats into the landing. So the longest defect is the sealing width minus two landings. Two hundred and ninety, minus two times fifty, is one hundred and ninety millimetres. That is less than half of the steel length.

  4. 1:13

    Pipe repair sleeve sizing: pass and reject examples

    Case one: a DN300 clay pipe with an open joint twenty-five millimetres wide. Each side keeps a hundred and thirty-two and a half millimetres of landing. Far above fifty. The sleeve passes. Case two: a DN250 concrete pipe with a two hundred and twenty millimetre crack. Each side keeps only thirty-five millimetres. The ribs land by the crack, and water tracks past the seal. Rejected. One sleeve cannot take this crack.

  5. 1:43

    Overlapping repair sleeves for longer defects

    For a defect from two hundred and fifty to six hundred millimetres, use two sleeves. The second sleeve overlaps the first by sixty to eighty millimetres. That overlap is what the rubber extension on the jacket is kept for. Past six to eight hundred millimetres of damage, sleeves stop being the economic answer. A resin patch or a full liner takes over there.

  6. 2:06

    What to measure before ordering a repair sleeve

    The landing also grows with the pipe. Fifty millimetres up to DN300, sixty-five to seventy-five from DN400 to DN600, and a hundred above DN600. At the factory, the shell length and the jacket width are both checked before the sleeve ships. Before you order a sleeve, send three measurements. The measured bore at the defect, and how far out of round it is. The defect length, start to stop, from slow CCTV. And the sound pipe you have on both sides of the defect. Send us the bore and the defect length, and we will check the sleeve fit.

Resources

Explainer videos and short demonstrations from Reliance’s official YouTube channels. Browse every published video by topic and follow each one to its reviewed watch page or official YouTube source.

All videos